Steel Glazed Fire Door ( As per DSR 2018 requirement) | ||
---|---|---|
1 | Door Type | Steel Glazed Fire Door |
2 | Criteria | Stability , Integrity with 20 min. insulation properties and 120 minutes radiation control properties as per NBC Guideline NBC 2016 |
3 | Rating | 120 mins |
4 | Shutter Thickness | 60mm |
5 | Testing Standards | BS 476 Part 20 - 22 , IS 3614 PART 2- 1992 |
6 | Test Laboratory | Certifire, Exova Warrington Fire Research Laboratory, United Kingdom , NABL Accredited test house - SPECTRO ANALYTICAL LAB , G. NOIDA etc. |
Steel Fire Rated Glazed Door (120 Mins)- ( As per DSR-2018 requirement) | ||
1 | Door Type | Steel Fire Rated Glazed Door tested with 11 mm thick FR Glass of Saint-Gobain make |
2 | Criteria | Stability & Integrity |
3 | Rating | 120 mins |
4 | Shutter Thickness | 46mm |
5 | Testing Standards | BS 476 Part 20 - 22, IS 3614 Part 2 |
6 | Test Laboratory | CBRI Roorkee, India |
Steel Fire Rated Glazed Door (60 mins) | ||
1 | Door Type | Steel Fire Rated Glazed Door tested with 6 mm thick single layered Fire rated Toughened FR Glass PYROSWISS E60 of Saint-Gobain make |
2 | Criteria | Stability & Integrity |
3 | Rating | 60 mins |
4 | Shutter Thickness | 50mm |
5 | Testing Standards | BS 476 Part 20 - 22, IS 3614 Part 2- 1992 |