Detail Description

  • Frame Manufactured out of Hardwood Mirandi / Teakwood of nominal section 140mm x 90mm
  • Hardwood Internal Timber Framework
  • Calcium Silicate Board
  • Shutter infill insulation – Wool insulation infill treated with VIPER FRS 881 LH
  • Intumescent Seal Size – 20mm x 4mm – 1 Nos for frame
  • Intumescent Seal Size – 20mm x 4mm – 1 No for door shutter
  • Both side 3mm Commercial Ply, Commercial ply with Laminate, teak veneer as per client requirement.

Acoustic Seal to achieve to acoustic properties 

To achieve Acoustic properties the air gap of the doors has to be reduced so as to create a barrier for the sound waves to travel across the face of the door. To reduce this gap Acoustic seal has to be provided . This db drop down properties is normally measured by means of db meter . Normally there is a gap on all the side of the door for movement requirement , therefore Drop down seal has to be provided in the bottom of the shutter , for the hinge gap a perimeter seal is normally provided in Perimeter of the frame. For Double leaf doors a Astragal seal needs to be provided . By using normal grade of seals 30 to 35 db drop down properties can be achieved approx.. we suggest Acoustic seal of  REVEN make , LORIENT seal & Enviro seal etc. However to enhance the higher db properties some extra seal can be provided. These doors are normally required for various requirement such as multiplex, Auditorium etc.

Recommended Finishes

1. Frame

  • Hardwood: VIPER Fire Retardant Primer FR 880 with VIPER Finishing Paint FRS 881
  • Teakwood: VIPER Fire Retardant Clear Polish FR881 Clear

2. Door Shutter

  • Painting with VIPER Fire Retardant Primer FR 880 with VIPER Finishing Paint FRS 881 – both sides
  • One side laminate / veneer and one side painting with VIPER Fire Retardant Primer FR 880 with VIPER Finishing Paint FRS 881
  • Both Sides Laminate / Veneer

Testing Criteria : we offer checking of db meter across by face of door.

Fire testing Certification : It is to bring kind notice that fire test houses does not offer any checking/testing of acoustic properties of any fire door as fire door is destructive things. Therefore we offer our esteemed client a copy of earlier test evidence for wooden fire doors along out MTC for fire rating.

 

Wooden Fire Rated Cum Acoustic Door
1 Criteria 3 Criteria : Fully Insulated
2 Rating upto 120 mins
3 Acoustic Rating 30-40 dB approximately (can be achieve by acoustic seal area)
4 Shutter Thickness 77 mm (Normal)
5 Testing Standards BS 476 Part 20 - 22, IS 3614 Part 2
6 Test Laboratory CBRI Roorkee, India. For wooden fire design